Replaces the Older Style Circuit Board Time Delay Relay. Same wiring hookup:
Lennox HS26-060-2P 24 Volt Time Delay Circuit Board used on many Models:HS26-461-1P, 93G1201, LB-59600B, LB-51378, 47J27, 47J35,
T90R5D12-24, 47J27.
New Upgraded Time Delay Replacement Control can be set to many on times, 3 wire hook up. Normally set time 5 minutes.
Adjustable time delay
Universal AC Voltage Operation.
Low Cost - Compact Size 2"x2"
Specifications:
InputControl Voltage: 18-240 VACFrequency: 50/60 HzPower Consumption: 3 watts max.OutputMaximum Rating: 1 ampMinimum Rating:
40mAIn-Rush: 10 ampsVoltage Drop: 2.5 V maximum @ 1.5 ampsLeakage Current: 5 ma max. @ 240 VAC
Installation 1.Disconnect Power 2. Connect terminals in series with the device. 3. Reapply power and check operation. for complete
diagrams, see installation guide: Timing Mode of OperationWhen power is applied to the input with the initiate switch open, the
load will remain energized indefinitely. Timing begins upon closure of the initiate or pressure switch. After the delay is complete,
the load is de-energized. When the initiate switch opens, before or after the delay, the control is reset.
Replaces Part Numbers: GKS00C, 2X100P, 47J27, CAR47J27.
|